Heating element Velox PH-750 VDC

VELOX PH-750 VDC, PARALLEL RESISTIVE HEATING CABLE (DOUBLE INSULATED)

ph750-vdc

  1. Conductor, tinned Cu, 1.5mm²
  2. Conductor insulation, Fluorplastic
  3. Bed for resistance wire
  4. Resistance wire Ni-Cr
  5. Sheath 1 Fluorplastic
  6. Sheath 2 Fluorplastic

 Range of application

Switch heating at railways, subways and tramways.

PH-750 VDC have a double sheath of corrosion hardened material (Teflon) and manages aggressive environmentals.

PH-750 VDC is double insulated and without earth screen.

Cable data

Basic type VDE 253 / IEC800
Approved, tested by CE
Color Green outer jacket
Test voltage 3000 V DC
Rated voltage 750 VDC
Output 70 W/m
Distance between contact points 2 meter
Max. Operating temperature 180°C
Max. exposure temperature max. +230°C
Installation temperature min -30°C
Bending radius min 50mm
Dimension 7.8 x 5.6 mm
Weight 75 kg/1000m

Note: Velox PH-750 VDC is installed on 750V with a channel of glass fibre plastic.

Table 1

Part.no Type of cable Output
+10°C
(W/m)
Length
max*
(m)
VX504 Velox PH-750 VDC 70 160

* at 10% powerloss

Insulation

phisolering

If two cables are installed parallel under same channel, standard channel, you will have a constant wattage parallel resistance cable with output up to 180W/m.

2 cables installed parallel under channel (ref.no: 6-18-9).