Heating element Origo-30 DC

VELOX SWITCHPOINT HEATING ELEMENT ORIGO30-DC, SELF-LIMITING HEATING CABLE

origo30-dc

  1. Insulation and outer sheath of (PFA)
  2. Semi-conductive material with self-limiting characteristics (the resistance increases with rising temperature)
  3. Conductors 2 x 1.3mm²

 

Range of application

Switch heating at railways, subways, tramways.

Cable data

Basic type Class II
Manufactured in accordance with VDE, IEC800
Cable class Double insulated***
Test voltage 1500 V DC
Rated voltage DC. Nominal 750 V.
Color Grey outer jacket
Operating temperature max. +150°C
Exposure temperature max. +250°C
Installation temperature min -20°C
Output/m at 10°C ~ 100/130W – 750V
Bending radius min 40mm
Dimension 11.5 x 6.5 mm
Weight 0.15 kg/m

Table 1

Type of cable Output
(W/m)
Length
max*
(m)
Velox Origo30-DC 100** 125

* at 10% power loss
** at 10°C

* Double insulated cable with each insulation layer thickness according to IEC:1995. R.M.S. 450/750 V. Minimum requirement 0.60mm.

Order information

Part.no Denomination
VX503 Velox Origo-30 DC

Velox ORIGO30-DC is manufactured with a sheath of PFA.