Origo-30 230/240 Vac

VELOX SWITCHPOINT HEATING ELEMENT ORIGO30-230/240, SELF-LIMITING HEATING CABLE

origo30_230240

  1.  Insulation and outer sheath of PFA
  2. Semi-conductive material with self-limiting characteristics (the resistance increases with rising temperature)
  3. Conductors 2 x 1.3mm²

Area of use

Switch heating at railways, subways, tramways.

Cable data

Basic type Class II
Manufactured in accordance with VDE, IEC800
Cable class Double insulated**
Test voltage 1500 V DC
Supply voltage 110/120 V
Colour: Red outer jacket
Operating temperature max. +150°C
Exposure temperature max. +250°C
Installation temperature min -20°C
Bending radius min 40mm
Dimension 11.5 x 6.5 mm
Weight 0.15 kg/m

Velox ORIGO30-230/240 is manufactured with a sheath of PFA

Table 1

Part.no Type of cable Output
(W/m)
Length
max*
(m)
VX500 Velox Origo30-230/240 100-110** 25

* at 10% power loss
** at 10°C

* Double insulated cable with each insulation layer thickness according to IEC:1995. R.M.S. 450/750 V. Minimum requirement 0.60mm.